ASDA-A3
8
U: DMCNET motion card
0: use Delta’s controller, such as PLC or HMI
3: use Delta’s motion card
Note:
1. If this parameter is set through CANopen, only Z can be set and the others remain unchanged.
2. The transmission speed of USB is set at 1.0 Mbit/s and cannot be changed.
3. After the Z value is set, cycle the power to take effect.
P3.002
Modbus communication protocol
Address: 0304H
0305H
Default: 0x0006
Control mode: All
Unit: -
Setting range: 0x0000 - 0x0008
Format: HEX
Data size: 16-bit
Settings:
Definition of each value:
0: 7, N, 2 (Modbus, ASCII)
3: 8, N, 2 (Modbus, ASCII)
6: 8, N, 2 (Modbus, RTU)
1: 7, E, 1 (Modbus, ASCII)
4: 8, E, 1 (Modbus, ASCII)
7: 8, E, 1 (Modbus, RTU)
2: 7, O, 1 (Modbus, ASCII)
5: 8, O, 1 (Modbus, ASCII)
8: 8, O, 1 (Modbus, RTU)
P3.003
Modbus communication error handling
Address: 0306H
0307H
Default: 0x0000
Control mode: All
Unit: -
Setting range: 0x0000 - 0x0001
Format: HEX
Data size: 16-bit
Settings:
0: display AL020 and let motor continue operating.
1: display AL020 and let motor decelerate to a stop. Deceleration time is set in P5.003.B.
P3.004
Modbus communication timeout
Default: 0
Unit: sec
Format: DEC
Control mode: All
Setting range: 0 to 20
Data size: 16-bit
Address: 0308H
0309H
Settings:
If the value is not 0, communication timeout is enabled immediately. To disable this function, set the
value to 0.