Parameters
P3.xxx Communication parameters
P3.000● Address
Default: 0x007F
Unit: -
Format: HEX
Settings:
Address: 0300H
0301H
Control mode: All
Setting
range:
0x0001
0x0001
-
-
0x007F (A3-M,
0xFFFF (A3-E)
A3-L,
A3-F)
Data size: 16-bit
8
U Z YX
YX Communication address setting
UZ Reserved
The address setting required for using RS-485, CANopen, and DMCNET communication. Make sure
there are no duplicate addresses in the same communication circuit, or it may cause communication
failure.
RS-485
When the master station sets the communication address to 0xFF, the address is always 0xFF in the
response message.
EtherCAT
When P3.018.A = 1, the address refers to the setting of P3.000; when P3.018.A = 0, the address must
be set by the controller.
P3.001Transmission speed
Default:
0x0203
0x3203
(A3-M,
(A3-F)
A3-L,
A3-E)
Unit: -
Format: HEX
Settings:
Address: 0302H
0303H
Control mode: All
Setting
range:
0x0000
0x0000
-
-
0x0405
0xF405
(A3-M,
(A3-F)
A3-L,
A3-E)
Data size: 16-bit
UZ YX
X RS-485 transmission speed
Y Reserved
Z CANopen / DMCNET transmission speed
U DMCNET motion card
X: RS-485 transmission speed
0: 4800 bps
1: 9600 bps
3: 38400 bps
4: 57600 bps
Z: CANopen / DMCNET transmission speed*3
2: 19200 bps
5: 115200 bps
0: 125 Kbps
3: 800 Kbps
1: 250 Kbps
4: 1.0 Mbps
2: 500 Kbps
-