Parameters
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA-A3
8
P2.113
Bandwidth of disturbance attenuation
Default: 50
Control mode: T
Address: 02E2H
02E3H
Unit: Hz
Setting range: 0 - 3000
Format: DEC
Data size: 16-bit
Settings:
The disturbance attenuation function is disabled when P2.114 is 0. It is recommended that you set
P2.113 to the default of 50. The higher you set P2.113, the more likely the high-frequency resonance is
to occur; the lower you set P2.113, the less the low-frequency vibration is suppressed.
P2.114
Level of disturbance attenuation
Default: 0
Control mode: T
Address: 02E4H
02E5H
Unit: -
Setting range: 0 - 500
Format: DEC
Data size: 16-bit
Settings:
The disturbance attenuation function is disabled when P2.114 is 0. Increasing this parameter can better
attenuate the disturbance. However, if you set the value too high, it may cause slower response and
system divergence.
P2.115 -
P2.120
Reserved
8-138