P2.106
Automatic gain adjustment level 2
Address: 02D4H
02D5H
Default: 2000
Control mode: All
Unit: pulse
Setting range: 1 to 50331648
Format: DEC
Data size: 32-bit
Settings:
Use this parameter to adjust the maximum allowable overshoot when auto-tuning. The overshoot range
is set according to either the user’s requirement or the machine characteristics. The higher the value,
the greater the maximum overshoot allowed by auto-tuning. However, the response is faster. The
smaller the value, the smaller the maximum overshoot allowed by auto-tuning. However, the response
is slower.
Pulse number
(Pulse)
Feedback
Command
P2.106
Time (sec)
P2.107
Rate of change for resonance suppression low-pass filter
Address: 02D6H
02D7H
Default: 100
Control mode: All
Unit: %
Setting range: 0 to 100
Format: DEC
Data size: 16-bit
Settings:
Adjusts the rate of change for the resonance suppression low-pass filter (P2.025) according to the
gain switching condition.
(This parameter is inversely proportional to the value of P2.025. The smaller the setting value of
P2.107, the stronger the filtering effect.)
P2.108 -
P2.111
Reserved