Parameters
P2.105
Automatic gain adjustment level 1
Default: 11
Unit: -
Format: DEC
Control mode: All
Setting range: 1 to 21
Data size: 16-bit
Address: 02D2H
02D3H
Settings:
Use this parameter to adjust the bandwidth when auto-tuning. The higher the value, the higher the
bandwidth after auto-tuning. However, the bandwidth margin may be insufficient, causing machine
jitter. The smaller the value, the lower the bandwidth after auto-tuning. However, the response is
slower.
Automatic gain
adjustment level 1
1 - 7
8 -14
15 - 21
Stiffness and response
Low stiffness and low
response
Medium stiffness and
medium response
High stiffness and high
response
Applicable mechanical parts
Belt, gear rack, reducer, cam
Screw
Direct-coupled mechanical parts
8
Value (dB)
High
bandwidth
Medium
bandwidth
Low
bandwidth
Frequency
(Hz)
P2.105 > 11
P2.105 = 11
P2.105 < 11