Send Quote Requests to info@automatedpt.com
ASDA-A3
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Parameters
P2.077
E-Cam: pulse masking and virtual pulse for master axis
Address: 029AH
029BH
Default: 0x0000
Control mode: PR
Unit: -
Setting range: 0x0000 - 0xFF7D
Format: HEX
Data size: 16-bit
Settings:
8
UZ Y X
Pulse masking function of master axis / pulse
X input method of master axis
Masking pulse / virtual pulse for initial lead
Y adjustment
Pulse data when master axis performs continuous
UZ forward / reverse running or JOG operation
- -
X: pulse masking function of master axis / pulse input method of master axis
X
0
1
2
3
4
5
6 to 8
9
A
B
C
D
Actual master
axis pulse
(P5.088.Y)
Function
Function
disabled
Actual
master
axis pulse
Received
Master axis
pulse masked
Continuous
forward running
Continuous
reverse running
Forward JOG
Masked
Reverse JOG
Reserved
-
Master axis
pulse masked
Continuous
forward running
Continuous
reverse running
Forward JOG
Received
Reverse JOG
+
Master axis
Slave axis
+
Virtual master
axis pulse
P2.077.UZ
Virtual
master axis
pulse
Disabled
Description
Slave axis is driven by the actual master axis pulse.
Slave axis stops operating, but the masked master
axis pulse continues to be stored in the internal
variable.
Enabled
-
Disabled
Enabled
Command source is the virtual pulse frequency (unit:
Kpps) set by P2.077.UZ. This function continues to
operate. To stop the virtual pulse, set X to 1.
Command source is the virtual pulse number (unit:
pulse) set by P2.077.UZ. This function only refers to
the pulse number set by P2.077.UZ.
-
Slave axis is driven by the actual master axis pulse
and the master axis pulse continues to be stored in
the internal variable.
Command source is the frequency transmitted by the
actual master axis (P5.088.Y) plus the virtual pulse
frequency (unit: Kpps) set by P2.077.UZ. This
function continues to operate. To stop the virtual
pulse, set X to 9.
Command source is the pulse transmitted by the
actual master axis (P5.088.Y) plus the virtual pulse
number (unit: pulse) set by P2.077.UZ. This function
is often used for dynamic adjustment.
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
8-125