Replacing the parts
Operating conditions:
Average annual ambient temperature: 30°C (86°F)
Average load rate: 80% or less
Average operating time: 20 hours per day
Product
Servo drive
Battery box
Servo motor
Part name
Electrolytic capacitor
Cooling fan
Relay
Soft start resistor
Battery
Bearing
Oil seal
Suggested replacement cycle
Approx. 5 years
2 to 3 years
(10,000 to 30,000 hours)
Approx. 100,000 times
Approx. 20,000 times
Refer to Section 10.1.1.
20,000 hours
5,000 hours
Note
The replacement cycle varies
depending on the ambient
conditions and usage. Replace
the part immediately when any
error occurs.
When the part reaches the suggested replacement cycle, consult the distributor or Delta for
replacement suggestions.
Do not attempt to disassemble or repair the product yourself.
Note: the content of this manual may be revised without prior notice. Refer to the latest information from Delta's website.