Send Quote Requests to info@automatedpt.com
ASDA-A3
P1.038
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Parameters
Bit 10
Motor speed
(Before conditions for switching
ZCLAMP to on are met)
Analog Speed command
Motor speed
(After conditions for
switching ZCLAMP to on
are met)
8
Bit 10 = 1 and command source is the internal register.
The ZCLAMP function uses the register Speed command with acceleration or deceleration to determine if this
function should be enabled. When ZCLAMP conditions are met, the motor speed is set to 0 rpm.
Motor speed
(Before conditions for switching ZCLAMP to on are met)
P1.038
Register Speed
command
Motor speed
(After conditions
for switching
ZCLAMP to on
are met)
Bit
Bit 11
Bit 12
Bit 13
Bit 14, Bit 15
Function
Pulse inhibit function
switch in PT mode
RST power error
(AL022) detection
function
Switch for OA and OB
output error (AL018 /
AL048) detection
Reserved
Description
0: disable PL / NL pulse inhibit function.
In PT mode, the servo drive receives pulse position
commands whether the motor reaches the PL or NL.
1: enable PL / NL pulse inhibit function.
In PT mode, if the motor reaches the PL, the servo
drive receives pulse position commands for negative-
direction operation and stops receiving pulse position
commands for positive-direction operation. In PT
mode, if the motor reaches the NL, the servo drive
receives pulse position commands for positive-
direction operation and stops receiving pulse position
commands for negative-direction operation.
0: enable the RST power error (AL022) detection
function.
1: disable the RST power error (AL022) detection
function.
0: enable OA and OB output error (AL018 / AL048)
detection.
1: disable OA and OB output error (AL018 / AL048)
detection.
-
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
8-117