Parameters
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA-A3
8
P2.060
E-Gear ratio - numerator N2
Default: 16777216
Unit: pulse
Format: DEC
Address: 0278H
0279H
Control mode: PT
Setting range: 1 to (229-1)
Data size: 32-bit
Settings:
The numerator of the E-Gear ratio can be selected with DI.GNUM0 and DI.GNUM1 (refer to Table 8.1).
If both DI.GNUM0 and DI.GNUM1 are not defined, P1.044 is the default numerator of the E-Gear ratio.
Switch DI.GNUM0 and DI.GNUM1 only when the servo is stopped in order to avoid mechanical
vibration.
GNUM0, GNUM1
Pulse
1st numerator (P1.044)
2nd numerator (P2.060)
3rd numerator (P2.061)
4th numerator (P2.062)
----------------------------
Denominator (P1.045)
Position
command
moving filter
(P1.068)
Smooth filter
(P1.008)
Pulse
Error
Feedback pulse
P2.061
E-Gear ratio - numerator N3
Default: 16777216
Unit: pulse
Format: DEC
Settings:
Refer to the description of P2.060.
Address: 027AH
027BH
Control mode: PT
Setting range: 1 to (229-1)
Data size: 32-bit
P2.062
E-Gear ratio - numerator N4
Default: 16777216
Unit: pulse
Format: DEC
Settings:
Refer to the description of P2.060.
Address: 027CH
027DH
Control mode: PT
Setting range: 1 to (229-1)
Data size: 32-bit
P2.063 -
P2.064
Reserved