Parameters
P2.040
DI13 functional planning
Default: 0x0100
Unit: -
Format: HEX
Address: 0250H
0251H
Control mode: All
Setting
range:
0x0000 - 0x015F
are DI codes)
(last
two
codes
Data size: 16-bit
Settings:
Refer to the description of P2.010. If there is no physical pin for DI13 on the model, use DI13 as a virtual
digital input when the number of physical DI points is insufficient or a trigger through communication.
You can set the DI to be used as soon as the servo power is on (e.g. Servo On) to be a virtual DI and
normally closed.
8
P2.041
DO6 functional planning
Default: 0x0100
Unit: -
Format: HEX
Settings:
Refer to the description of P2.018.
Address: 0252H
0253H
Control mode: All
Setting
range:
0x0000
are DO
- 0x013F
codes)
(last
two
codes
Data size: 16-bit
P2.042
Reserved
P2.043
Notch filter 2 - frequency
Default: 1000
Unit: Hz
Format: DEC
Address: 0256H
0257H
Control mode: All
Setting range: 50 to 5000
Data size: 16-bit
Settings:
The resonance frequency of the second Notch filter. This function is disabled if P2.044 is 0. P2.043,
P2.044, and P2.096 are the second set of Notch filter parameters.
P2.044
Notch filter 2 - attenuation level
Default: 0
Unit: -dB
Format: DEC
Control mode: All
Setting range: 0 to 40
Data size: 16-bit
Address: 0258H
0259H
Settings:
The attenuation level of the second Notch filter. A value of 5 indicates -5 dB. Set this parameter to 0 to
disable the second Notch filter.