ASDA-A3
P2.033
Reserved
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Parameters
P2.034
Excessive
deviation
warning
condition
of
Speed
command
Address:
0244H
0245H
Default: 5000
Control mode: S / Sz
Unit:
1
1
rpm (rotary)*
mm/s (linear)*
Format: DEC
Setting range: 1 to 30000 (rotary)*
1 to 15999 (linear)*
Data size: 16-bit
Settings:
In Speed mode, this parameter sets the acceptable difference between the command speed and the
feedback speed. If the difference is greater than this value, AL007 occurs.
Note: when P2.094 [Bit 6] = 1, this parameter is available in both Position mode (PT, PR) and Speed mode (S, Sz).
P2.035
Excessive deviation warning condition of Position
command
Address: 0246H
0247H
Default: 50331648
Control mode: PT / PR
Unit: pulse
Setting range: 1 to 1677721600
Format: DEC
Data size: 32-bit
Settings:
In Position mode, this parameter sets the acceptable difference between the command position and the
feedback position. If the difference is greater than this value, AL009 occurs.
P2.036
DI9 functional planning
Default: 0x0100
Unit: -
Format: HEX
Address: 0248H
0249H
Control mode: All
Setting
range:
0x0000 - 0x015F
are DI codes)
(last
two
codes
Data size: 16-bit
Settings:
Refer to the description of P2.010. If there is no physical pin for DI9 on the model, use DI9 as a virtual
digital input when the number of physical DI points is insufficient or a trigger through communication.
You can set the DI to be used as soon as the servo power is on (e.g. Servo On) to be a virtual DI and
normally closed.