Send Quote Requests to info@automatedpt.com
ASDA-A3
P2.021
DO4 functional planning
0x0105 (A3-L, A3-M)
Default: 0x0007 (A3-F, A3-E)
Unit: -
Format: HEX
Settings:
Refer to the description of P2.018.
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Parameters
Address: 022AH
022BH
Control mode: All
Setting range: 0x0000 - 0x014F (last two codes
are DO codes)
Data size: 16-bit
8
P2.022
DO5 functional planning
Default: 0x0007 (A3-L, A3-M)
0x0100 (A3-F, A3-E)
Unit: -
Format: HEX
Settings:
Refer to the description of P2.018.
Address: 022CH
022DH
Control mode: All
Setting
range:
0x0000
are DO
- 0x014F
codes)
(last
two
codes
Data size: 16-bit
P2.023
Notch filter 1 - frequency
Default: 1000
Unit: Hz
Format: DEC
Address: 022EH
022FH
Control mode: All
Setting range: 50 to 5000
Data size: 16-bit
Settings:
The resonance frequency of the first Notch filter. This function is disabled if P2.024 is 0. P2.023, P2.024,
and P2.095 are the first set of Notch filter parameters.
P2.024
Notch filter 1 - attenuation level
Default: 0
Unit: -dB
Format: DEC
Control mode: All
Setting range: 0 to 40
Data size: 16-bit
Address: 0230H
0231H
Settings:
The attenuation level of the first Notch filter. A value of 5 indicates -5 dB. Set this parameter to 0 to
disable the first Notch filter.
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
8-99