Send Quote Requests to info@automatedpt.com
ASDA-A3
P2.015
DI6 functional planning
0x0022 (A3-L, A3-M)
Default: 0x0023 (A3-F, A3-E)
Unit: -
Format: HEX
Settings:
Refer to the description of P2.010.
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Parameters
Address: 021EH
021FH
Control mode: All
Setting range: 0x0000 - 0x015F (last two codes
are DI codes)
Data size: 16-bit
8
P2.016
DI7 functional planning
Default: 0x0023 (A3-L, A3-M)
0x0021 (A3-F, A3-E)
Unit: -
Format: HEX
Settings:
Refer to the description of P2.010.
Address: 0220H
0221H
Control mode: All
Setting
range:
0x0000 - 0x015F
are DI codes)
(last
two
codes
Data size: 16-bit
P2.017
DI8 functional planning
0x0021 (A3-L, A3-M)
Default: 0x0100 (A3-F, A3-E)
Unit: -
Format: HEX
Address: 0222H
0223H
Control mode: All
Setting
range:
0x0000 - 0x015F
are DI codes)
(last
two
codes
Data size: 16-bit
Settings:
Refer to the description of P2.010.
There is no physical pin for DI8 on A3-F and A3-E models. DI8 is a virtual digital input which you can
use when the number of physical DI points is insufficient or to trigger through communication. You can
set the DI to be used as soon as power is on when the contact would be normally closed for virtual
digital input, such as Servo On.
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com