Parameters
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA-A3
8
Z: input contact: A or B contact
0: set this input contact to be normally closed (B contact)
1: set this input contact to be normally open (A contact)
When these parameters are modified, re-start the servo drive to ensure it functions normally. Use
P3.006 to change the source for the digital input signal, which can be either an external terminal block
or the communication parameter P4.007.
P2.011
DI2 functional planning
Default:
0x0104
0x0100
(A3-L,
(A3-F,
A3-M)
A3-E)
Unit: -
Format: HEX
Settings:
Refer to the description of P2.010.
Address: 0216H
0217H
Control mode: All
Setting
range:
0x0000 - 0x015F
are DI codes)
(last
two
codes
Data size: 16-bit
P2.012
DI3 functional planning
Default:
0x0116
0x0100
(A3-L,
(A3-F,
A3-M)
A3-E)
Unit: -
Format: HEX
Settings:
Refer to the description of P2.010.
Address: 0218H
0219H
Control mode: All
Setting
range:
0x0000 - 0x015F
are DI codes)
(last
two
codes
Data size: 16-bit
P2.013
DI4 functional planning
Default:
0x0117
0x0124
(A3-L,
(A3-F,
A3-M)
A3-E)
Unit: -
Format: HEX
Settings:
Refer to the description of P2.010.
Address: 021AH
021BH
Control mode: All
Setting
range:
0x0000 - 0x015F
are DI codes)
(last
two
codes
Data size: 16-bit
8-96
P2.014
DI5 functional planning
Default:
0x0102
0x0022
(A3-L,
(A3-F,
A3-M)
A3-E)
Unit: -
Format: HEX
Settings:
Refer to the description of P2.010.
Address: 021CH
021DH
Control mode: All
Setting range: 0x0000 - 0x015F (last two codes
are DI codes)
Data size: 16-bit
Send Quote Requests to info@automatedpt.com