Parameters
P2.008Special parameter write-in function
Default: 0
Unit: -
Format: DEC
Control mode: All
Setting range: 0 to 501
Data size: 16-bit
Address: 0210H
0211H
Settings:
Special parameter write-in function:
Setting value
10
18
20
22
30, 35
406
400
Function
Reset parameter groups P0 - P7 (cycle the power after reset).
Reset parameter group PM (cycle the power after reset).
P4.010 is writable.
P4.011 - P4.021 are writable.
Save Compare, Capture, and E-Cam data.
Enable forced DO mode.
When forced DO mode is enabled, switch back to the normal DO mode.
8
P2.009
DI response filter time
Default: 2
Unit: ms
Format: DEC
Control mode: All
Setting range: 0 to 100
Data size: 16-bit
Address: 0212H
0213H
Settings:
When environmental interference is high, increasing this value can enhance the control stability. If you
set the value too high, it affects the response time.
P2.010
DI1 functional planning
0x0101 (A3-L, A3-M)
Default: 0x0100 (A3-F, A3-E)
Unit: -
Format: HEX
Settings:
Address: 0214H
0215H
Control mode: All
Setting
range:
0x0000 - 0x015F
are DI codes)
(last
two
codes
Data size: 16-bit
U Z YX
YX Input function selection
- -
YX: input function selection
Refer to Table 8.1.
Z Input contact: A or B contact
U Reserved