ASDA-A3
8
P1.101
Analog monitor output voltage 1
Address: 01CAH
01CBH
Default: 0
Control mode: All
Unit: mV
Setting range: -10000 to +10000
Format: DEC
Data size: 16-bit
Settings:
When you set 6 for the monitor source of P0.003 [YX], then the analog monitor output voltage refers to
the voltage value of P1.101.
Note: the valid setting range is -8V to +8V.
P1.102
Analog monitor output voltage 2
Address: 01CCH
01CDH
Default: 0
Control mode: All
Unit: mV
Setting range: -10000 to +10000
Format: DEC
Data size: 16-bit
Settings:
When you set 7 for the monitor source of P0.003 [YX], then the analog monitor output voltage refers to
the voltage value of P1.102.
Note: the valid setting range is -8V to +8V.
P1.103 -
P1.104
Reserved
P1.105
Motor hard stop 2 - torque upper limit
Address: 01D2H
01D3H
Default: 0
Control mode: All
Unit: %
Setting range: -300 to +300
Format: DEC
Data size: 16-bit
Settings:
When Motor hard stop 2 is enabled (P2.112 [Bit 8] = 1), the settings of torque percentage (P1.057) and
level offset (P1.060) for Motor hard stop 1 are invalid. During motor operation, if the motor torque is
higher than this protection setting value and the duration of this condition exceeds the protection time
(P1.058), AL030 will be triggered.
Torque
8-90
P1.105
P1.106
AL030
Time
P1.058