Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA-A3
Parameters
Example:
1. Set P2.094 = 0x11 to enable the first set.
2. Set P2.094 = 0x12 to enable the second set.
3. Set P2.094 = 0x13 to enable the first and second sets simultaneously.
P1.090
Vibration elimination 1 - resonance frequency
Address: 01B4H
01B5H
Default: 4000
Control mode: PT / PR
Unit: 0.1 Hz
Setting range: 10 to 4000
Format: DEC
Data size: 16-bit
Settings:
Resonance frequency for the first set of low frequency vibration elimination.
8
P1.091
Vibration elimination 1 - resonance difference
Address: 01B6H
01B7H
Default: 10
Control mode: PT / PR
Unit: 0.1 dB
Setting range: 10 to 4000
Format: DEC
Data size: 16-bit
Settings:
Attenuation rate for the first set of low frequency vibration elimination.
P1.092
Vibration elimination 2 - anti-resonance frequency
Address: 01B8H
01B9H
Default: 4000
Control mode: PT / PR
Unit: 0.1 Hz
Setting range: 10 to 4000
Format: DEC
Data size: 16-bit
Settings:
Anti-resonance frequency for the second set of low frequency vibration elimination. The setting method
is the same as the first set of vibration elimination (P1.089).
P1.093
Vibration elimination 2 - resonance frequency
Address: 01BAH
01BBH
Default: 4000
Control mode: PT / PR
Unit: 0.1 Hz
Setting range: 10 to 4000
Format: DEC
Data size: 16-bit
Settings:
Resonance frequency for the second set of low frequency vibration elimination.
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
8-87