Send Quote Requests to info@automatedpt.com
Parameters
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA-A3
8
X: setting for position command issued by the analog signal
0: disable
1: enable
Y: initial position setting
0: after the servo is on, the motor regards the current position as the position when the voltage is
0V. Then the motor operates to the corresponding position according to the analog input
command.
Motor position (Turn)
When this function is executed, the
motor operates to the position
corresponding to the current voltage
command
Current position is regarded as the
position when 0V
Current command
level
Analog input command (V)
1: after the servo is on, if the command level is not changed, the motor does not operate. The
position the motor stops at is the position corresponding to the current command level.
Motor position (Turn)
Motor current
position
Position
corresponding
to 0V does not
change
When this function is executed,
the motor does not operate if the
command level is not changed.
Command level
Analog input
command (V)
P1.065
Analog Position command - smoothing constant
Address: 0182H
0183H
Default: 1
Control mode: PT
Unit: 10 ms
Setting range: 1 to 1000
Format: DEC
Data size: 16-bit
Settings:
The smooth constant of analog Position command is only effective to analog Position command.
8-76
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com