ASDA-A3
Holding time
Original step analog
Speed command
8
Command that has gone
through analog speed
linear filtering
P1.060
Motor hard stop 1 - level offset
Default: 0
Unit: %
Format: DEC
Address: 0178H
0179H
Control mode: All
Setting range: -300 to +300
Data size: 16-bit
Settings:
When using P1.057 (Motor hard stop 1 - torque percentage) and the average torque level deviates due
to an external force, such as Z-axis gravity, you can use this parameter to set the corresponding
compensation.
Suggested setting value = (Average torque at constant speed in positive direction + Average torque at
constant speed in negative direction) / 2
Note: refer to P0.002 = 54 (Torque feedback) for the average torque at constant speed.
P1.061
Viscous friction compensation
Default: 0
Unit:
0.1%/1000
0.1%/1000
rpm (rotary)*
mm/s (linear)*
Format: DEC
Address: 017AH
017BH
Control mode: PT / PR / S / Sz
Setting range: 0 to 1000
Data size: 16-bit
Settings:
Because viscous friction corresponds with the speed, you can use this parameter to compensate the
motor torque according to the speed to improve the position error during acceleration and deceleration.
When P1.062 = 0, this parameter is invalid.
Frict io n
Frict io n
Frict io n
Speed
Speed
Speed
P1.062 Percentage of friction compensation
P1.063 Constant of friction compensation
P1.061 Viscous friction compensation
P1.062 Percentage of friction compensation
P1.063 Constant of friction compensation
P1.061 Viscous friction compensation
Note: rotary means a permanent-magnet synchronous rotary motor; linear means a permanent-magnet synchronous
linear motor.
8-74