Send Quote Requests to info@automatedpt.com
ASDA-A3
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Parameters
P1.053
Regenerative resistor capacity
Default:
Determined by the
the following table.
model.
Refer
to
Unit: Watt
Format: DEC
Address: 016AH
016BH
Control mode: All
Setting range: 0 to 15000
Data size: 16-bit
Settings:
220V
400V
Model
200 W or below
400 W - 1.5 kW
2 kW - 3 kW
4.5 kW
5.5 kW - 7.5 kW
11 kW - 15 kW
1.5 kW or below
2 kW - 15 kW
Default (Watt)
0
40
80
60
0
0
60
0
Setting the parameter value when connecting the regenerative resistor with different methods:
External regenerative resistor
Setting
Exte rnal rege nerative
resistor
P3
1 kW, 10 Ω
C
Setting:
P1.052 = 10 (Ω)
P1.053 = 1000 (W)
Exte rnal rege nerative
resistor (series)
P3
1 kW, 10 Ω
1 kW, 10 Ω
C
Setting:
P1.052 = 20 (Ω)
P1.053 = 2000 (W)
Exte rnal rege nerative
resistor (para llel)
P3
1 kW, 10 Ω
1 kW, 10 Ω
C
Setting:
P1.052 = 5 (Ω)
P1.053 = 2000 (W)
8
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
8-71