Send Quote Requests to info@automatedpt.com
Parameters
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA-A3
8
P1.038
Zero speed range
Operation
interface:
Panel
/
software
Default: 10.0
Unit:
1
1
rpm (rotary)*
mm/s (linear)*
Setting range: 0.0 to 200.0
Communication
100
0.1 rpm (rotary)*
0.1 mm/s (linear)*
0 to 2000
Address: 014CH
014DH
Control mode: All
Data size: 16-bit
-
-
-
-
Format: One decimal
Example: 1.5 = 1.5 rpm
1.5 = 1.5 mm/s
DEC
15 = 1.5 rpm
15 = 1.5 mm/s
-
-
-
-
Settings:
Sets the range for the zero-speed signal (ZSPD). When the absolute value of the motor speed is lower
than this value, the zero-speed signal is triggered and DO.ZSPD is on.
Note: rotary means a permanent-magnet synchronous rotary motor; linear means a permanent-magnet synchronous
linear motor.
P1.039
Target speed detection level
Default: 3000
Unit:
1
1
rpm (rotary)*
mm/s (linear)*
Format: DEC
Address: 014EH
014FH
Control mode: All
Setting
range:
0
0
to
to
30000
15999
(rotary)*
(linear)*
Data size: 16-bit
Settings:
Sets the motor target speed. When the absolute value of the motor speed is higher than this value, the
condition for triggering the target speed reached signal is met and DO.TSPD is on.
Note: rotary means a permanent-magnet synchronous rotary motor; linear means a permanent-magnet synchronous
linear motor.
P1.040
Maximum motor speed for analog Speed command 1
Address: 0150H
0151H
Default: Rated speed
Unit:
1
1
rpm (rotary)*
mm/s (linear)*
Format: DEC
Control mode: S / T
Setting
range:
0
0
to
to
50000
15999
(rotary)*
(linear)*
Data size: 32-bit
Settings:
In Speed mode:
Sets the motor speed corresponding to 10V (maximum voltage) for the analog Speed command.
Speed control command = Input voltage×P1.040
10
If the value is 2000 and the external voltage input is 5V, then the speed control command = 5V×2000 =
10V
1000 rpm (1000 mm/s).
8-64
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com