Parameters
P1.030
Low-frequency vibration detection
Address: 013CH
013DH
Default: 8000
Control mode: PT / PR
Unit: pulse
Setting range: 1 to 128000
Format: DEC
Data size: 32-bit
Settings:
Sets the detection level when automatic vibration suppression is enabled (P1.029 = 1). The lower the
value, the more sensitive the detection, but the system may also misjudge noise or treat other low-
frequency vibrations as frequencies to be suppressed. If the value is high, the system is less likely to
misjudge, but if the vibration of the machine is small, the system may not properly detect low-frequency
vibrations.
8
P1.031
Reserved
P1.032
Motor stop mode
Default: 0x0000
Unit: -
Format: HEX
Settings:
Address: 0140H
0141H
Control mode: All
Setting range: 0x0000 to 0x0020
Data size: 16-bit
UZ YX
X Reserved
Z
Y Motor stop mode
U
Y: motor stop mode
Bit 7 6 5 4 3 2 1 0
Y
Bit 15 14 13 12 11 10 9 8
Reserved
Reserved
Bit
Bit 5, Bit 4
Bit 6
Bit 7
Function
Dynamic brake
operation options
Trigger stop
command when
RST power error
(AL022) occursNote
Reserved
Description
Options for stopping the motor when the servo is in the Servo
Off state or an alarm (including EMGS) occurs.
Bit 5 = 0 and Bit 4 = 0: use dynamic brake
Bit 5 = 0 and Bit 4 = 1: motor runs freely
Bit 5 = 1 and Bit 4 = 0: use dynamic brake first, and then let the
motor run freely once the speed is slower than the value of
P1.038
0: disable this function.
1: when P1.043 is a negative value and RST power error
(AL022) occurs, the servo drive commands the motor to
decelerate to 0 in the Servo On state.
-