Send Quote Requests to info@automatedpt.com
ASDA-A3
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Installation
2.5 Specifications for the circuit breaker, magnetic contactor
and fuse
220V models
Servo drive model
ASD-A3-0121-
ASD-A3-0221-
ASD-A3-0421-
ASD-A3-0721-
ASD-A3-1021-
ASD-A3-1521-
ASD-A3-2023-
ASD-A3-3023-
ASD-A3-4523-
ASD-A3-5523-
ASD-A3-7523-
ASD-A3-1B23-
ASD-A3-1F23-
Control circuit power (L1C, L2C)
Circuit breaker
Magnetic contactor (MC)
1 A
1 A
1 A
1 A
1 A
1 A
3 A
3 A
3 A
3 A
3 A
3 A
3 A
3 A
3 A
3 A
5 A
5 A
5 A
5 A
5 A
5 A
5 A
5 A
5 A
5 A
Fuse (Class T)
1 A
1 A
1 A
3 A
3 A
3 A
3 A
3 A
6 A
6 A
6 A
6 A
6 A
Servo drive model
ASD-A3-0121-
ASD-A3-0221-
ASD-A3-0421-
ASD-A3-0721-
ASD-A3-1021-
ASD-A3-1521-
ASD-A3-2023-
ASD-A3-3023-
ASD-A3-4523-
ASD-A3-5523-
ASD-A3-7523-
ASD-A3-1B23-
ASD-A3-1F23-
Main circuit power (RST)
Circuit breaker
Magnetic contactor (MC)
5 A
5 A
5 A
5 A
10 A
10 A
10 A
10 A
15 A
15 A
20 A
20 A
30 A
30 A
30 A
30 A
70 A
70 A
75 A
75 A
95 A
95 A
110 A
110 A
120 A
120 A
Fuse (Class T)
5 A
5 A
10 A
20 A
25 A
35 A
50 A
70 A
100 A
150 A
150 A
200 A
200 A
Note:
1. In the servo drive model name, represents the model type.
2. Operation mode: standard.
3. If the servo drive is equipped with a residual-current device (RCD) for electricity leakage protection,
select a circuit breaker with sensitivity of at least 200 mA and with minimum 0.1 sec working time to
avoid incorrect operation of the RCD.
4. Select the Type B residual-current device (RCD) with time delay, as the system ground wire may
contain DC electricity.
5. Use the fuse and circuit breaker that comply with the UL / CSA standard.
2