Send Quote Requests to info@automatedpt.com
Parameters
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA-A3
8
X: additional function for Capture
Bit 3 2 1 0
Bit
0
1 to 3
Function
Cycle
mode
Reserved
Description
Set this bit to 0 to disable this function. When the number of capturing times
(P5.038) is 0, capturing is complete.
Set this bit to 1 to enable this function. When the number of capturing times
(P5.038) is 0, the servo drive automatically resets the number of capturing
times to the default setting.
-
Z: additional function for Compare
Bit 3 2 1 0
Bit
0
1 to 3
Function
P1.024 is
reset to 0
automatically
Reserved
Description
Set this bit to 0 to disable this function. The value of P1.024 remains after the
comparing is complete.
Set this bit to 1 to enable this function. P1.024 automatically resets to 0 after
taking effect once.
-
P1.020
Capture: masking range
Default: 0
Unit: Pulse unit of capture source
Format: DEC
Address: 0128H
0129H
Control mode: All
Setting range: 0 to +100000000
Data size: 32-bit
Settings:
When the Capture function is enabled and set to capture multiple points (P5.038 > 1), use this
parameter to set the range within which the system stops receiving the DI captured signal once the data
is captured. The DI captured signal received within this range is not recognized as valid. Use this
function to prevent the system from seeing noise as effective signals within the non-capture range.
P1.020 masking P1.020 masking
pulse number
pulse number
Masking area
The system activates the masking area after capturing this mark.
8-56
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com