Send Quote Requests to info@automatedpt.com
ASDA-A3
P1.002▲ Speed and torque limits
Default: 0x0000
Unit: -
Format: HEX
Settings:
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Parameters
Address: 0104H
0105H
Control mode: All
Setting range: 0x0000 - 0x0011
Data size: 16-bit
8
UZ YX
X Disable / enable Speed Limit function
Y Disable / enable Torque Limit function
UZ Reserved
-
-
X: disable / enable Speed Limit function
0: disable Speed Limit function
1: enable Speed Limit function (only available in T and Tz modes)
See the following diagram for Speed Limit setting:
Vref
(0)
(Analog
command)
P1.009 (1)
P1.010 (2)
P1.011 (3)
Select by DI.SPD0 and DI.SPD1
Speed Limit
command
Y: disable / enable Torque Limit function
0: disable Torque Limit function
1: enable Torque Limit function
See the following diagram for Torque Limit setting:
Vref
(0)
(Analog
command)
P1.012 (1)
P1.013 (2)
P1.014 (3)
Select by DI.TCM0 and DI.TCM1
Torque Limit
command
When using the Torque Limit function, set P1.002.Y to 1 to enable the Torque Limit function
permanently without occupying a DI setting. Alternatively, you can enable or disable the Torque
limit function with DI.TRQLM, which is more flexible, but the setting then occupies a DI setting.
You can enable the Torque Limit function by either P1.002 or DI.
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
8-47