Send Quote Requests to info@automatedpt.com
Parameters
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA-A3
8
P0.053
General range compare digital output - filter time
Address: 006AH
006BH
Default: 0x0000
Control mode: All
Unit: -
Setting range: 0x0000 - 0xFFFF
Format: HEX
Data size: 16-bit
Settings:
UZ YX
X First filter time
Y Second filter time
Z Third filter time
U Fourth filter time
Note: the minimum filter time is 1 ms (set value 0 = 1 ms; 1 = 2 ms; 2 = 3 ms; ...; F = 16 ms).
Example of the first filter:
P0.055
P0.054
P0.009 monitoring
item value
On
DO: 0x2C
Off
P0.053.X
filter time
P0.053.X
filter time
P0.054
General range compare digital output 1 - lower limit
Address: 006CH
006DH
Default: 0
Control mode: All
Unit: -
Setting range: -2147483648 to +2147483647
Format: DEC
Data size: 32-bit
Settings:
Before using this function, set the digital output function to 0x2C (first set of general range comparison)
and the monitoring item of P0.017.
When the monitoring item value of P0.009 is within the range set by P0.054 and P0.055, and after the
filter time set by P0.053.X, this digital output is on.
P0.055
General range compare digital output 1 - upper limit
Address: 006EH
006FH
Default: 0
Control mode: All
Unit: -
Setting range: -2147483648 to +2147483647
Format: DEC
Data size: 32-bit
Settings:
Refer to the description of P0.054.
8-38
Send Quote Requests to info@automatedpt.com