Send Quote Requests to info@automatedpt.com
ASDA-A3
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Parameters
P0.050★■ Absolute position system status
Address: 0064H
0065H
Default: 0x0000
Control mode: All
Unit: -
Setting range: 0x0000 - 0x001F
Format: HEX
Data size: 16-bit
Settings:
Bit 7 6 5 4 3 2 1 0
Bit 15 14 13 12 11 10 9 8
8
Bit
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5 - Bit 15
Function
Absolute position status
Battery voltage status
Status of absolute
number of turns
PUU status
Absolute position status
Reserved
0: normal.
1: lost.
0: normal.
1: undervoltage.
0: normal.
1: overflows.
0: normal.
1: overflows.
0: established.
1: not yet established.
-
Description
P0.051★■ Encoder absolute position - number of revolutions
Address: 0066H
0067H
Default: 0
Control mode: All
Unit: rev
Setting range: -32768 to +32767
Format: DEC
Data size: 16-bit
Settings:
When you set P2.070 [Bit 1] to 1 for reading the pulse number, this parameter displays the encoder’s
absolute position in the form of number of revolutions. When you set P2.070 [Bit 1] to 0 for reading the
PUU number, this parameter becomes invalid and the panel displays 0.
P0.052★■
Encoder absolute position - pulse number within single Address: 0068H
turn or PUU
0069H
Default: 0
Control mode: All
Unit: pulse or PUU
Format: DEC
0 to 16777216-1 (pulse)
Setting range: -2147483648 to +2147483647
(PUU)
Data size: 32-bit
Settings:
When you set P2.070 [Bit 1] to 1 for reading the pulse number, this parameter displays the encoder’s
absolute position in the form of pulse number within a single turn. When you set P2.070 [Bit 1] to 0 for
reading the PUU number, this parameter displays the motor’s absolute position in PUU.
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
8-37