Parameters
P0.042
Target setting for mapping parameter P0.032
Address: 0054H
0055H
Default: -
Control mode: All
Unit: -
Setting
range:
Determined by
address of the
the communication
parameter group
Format: HEX
Data size: 32-bit
Settings:
P0.042
High word
Par ame ter to b e
mappe d
Low word
Par ame ter to b e
mappe d
P0.032
Content of
Content of
mappin g p arameter mappin g p arameter
8
P0.043
Reserved
P0.044Status monitoring register (for PC software)
Address: 0058H
0059H
Default: 0
Control mode: All
Unit: -
Setting
range:
Determined by
address of the
the communication
parameter group
Format: DEC
Data size: 32-bit
Settings:
This setting is the same as P0.009.
P0.045
Status monitoring register content selection (for PC
software)
Address: 005AH
005BH
Default: 0
Control mode: All
Unit: -
Setting range: -300 to +127
Format: DEC
Data size: 16-bit
Settings: