ASDA-A3
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Parameters
P0.019
Select content displayed by status monitoring register 3
Address: 0026H
0027H
Default: 0
Control mode: All
Unit: -
Setting range: -300 to +127
Format: DEC
Data size: 16-bit
Settings:
Refer to Table 8.3 for the available values.
8
P0.020
Select content displayed by status monitoring register 4
Address: 0028H
0029H
Default: 0
Control mode: All
Unit: -
Setting range: -300 to +127
Format: DEC
Data size: 16-bit
Settings:
Refer to Table 8.3 for the available values.
P0.021
Select content displayed by status monitoring register 5
Address: 002AH
002BH
Default: 0
Control mode: All
Unit: -
Setting range: -300 to +127
Format: DEC
Data size: 16-bit
Settings:
Refer to Table 8.3 for the available values.
P0.022 -
P0.024
Reserved
P0.025■ Mapping parameter 1
Default: -
Unit: -
Format: HEX
Address: 0032H
0033H
Control mode: All
Setting
range:
Determined by the
parameter P0.035
corresponding
Data size: 32-bit
Settings:
You can continuously read and write parameters faster if they are not in the same group. Use P0.035 to
specify the parameter number to be read or written with the mapping parameter through the panel or
communication. The value of the parameter that is specified by P0.035 is shown in P0.025. Refer to
P0.035 for its settings.