ASDA-A3
8
P0.012★■ Status monitoring register 4
Default: -
Unit: -
Format: DEC
Control mode: All
Setting range: -
Data size: 32-bit
Address: 0018H
0019H
Settings:
Set the value to be monitored in P0.020 through the drive panel or communication. Please refer to
P0.002. To get the status, read the communication address through the communication port. Set P0.002
to 26 and the panel displays “VAR-4” and then the value of P0.012.
P0.013★■ Status monitoring register 5
Default: -
Unit: -
Format: DEC
Control mode: All
Setting range: -
Data size: 32-bit
Address: 001AH
001BH
Settings:
Set the value to be monitored in P0.021 through the drive panel or communication. Please refer to
P0.002. To get the status, read the communication address through the communication port.
P0.014 -
P0.016
Reserved
P0.017
Select content displayed by status monitoring register 1
Address: 0022H
0023H
Default: 0
Control mode: All
Unit: -
Setting range: -300 to +127
Format: DEC
Data size: 16-bit
Settings:
Refer to Table 8.3 for the available values.
For example, if you set P0.017 to 7, then reading P0.009 displays the motor speed (0.1 rpm) at present.
P0.018
Select content displayed by status monitoring register 2
Address: 0024H
0025H
Default: 0
Control mode: All
Unit: -
Setting range: -300 to +127
Format: DEC
Data size: 16-bit
Settings:
Refer to Table 8.3 for the available values.