Parameters
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA-A3
X MON2
Y MON1
UZ Reserved
- -
8
MON1 and MON2
set value
0
1
2
3
Description
Motor speed
(+/- 8 volts / Maximum speed)
Motor torque
(+/- 8 volts / Maximum torque)
Pulse command frequency
(+8 volts / 4.5 Mpps)
Speed command
(+/- 8 volts / Maximum Speed
command)
MON1 and MON2
set value
4
5
6
7
Description
Torque command
(+/- 8 volts / Maximum Torque
command)
VBUS voltage
(+/- 8 volts / 450V)
Analog output voltage is the set
value of P1.101
Analog output voltage is the set
value of P1.102
Note: refer to P1.004 and P1.005 for the proportional setting for the analog output voltage.
For example: when you set P0.003 to 01 (MON1 is the analog output of motor speed; MON2 is the analog
output of motor torque):
MON1 output voltage =
8 x
Motor speed
(Maximum speed x P1.004)
(Unit: volts)
100
MON2 output voltage =
8 x
Motor torque
(Maximum torque x P1.005)
(Unit: volts)
100
P0.004 -
P0.007
Reserved
P0.008Total servo drive operation time
Address: 0010H
0011H
Default: 0x00000000
Control mode: All
Unit: hour
Setting range: 0x00000000 - 0xFFFFFFFF
Format: HEX
Data size: 32-bit
Settings:
Displays the total servo drive operation and Servo On time. The unit is in hours and durations of less
than 1 hour are not recorded. The recorded hours are saved when the servo power is off.
High word
Low word
D CB A
DCBA Servo On time
U Z Y X
UZYX Servo power applied time
8-26