Parameters
8.3 Parameter descriptions
P0.xxx Monitoring parameters
P0.000Firmware version
Default: Factory setting
Unit: -
Format: DEC
Control mode: All
Setting range: -
Data size: 16-bit
Settings:
Displays the firmware version of the servo drive.
Address: 0000H
0001H
8
P0.001■ Current drive alarm code (seven-segment display)
Address: 0002H
0003H
Default: -
Control mode: All
Unit: -
Format: HEX
0x0000: alarm clear (same as
Setting range: DI.ARST).
0x0001 - 0xFFFF: displays the
alarm code (not writable).
Data size: 16-bit
Settings:
For the list of alarms, refer to Section 14.1 Alarm list.
P0.002
Drive status
Default: 1
Unit: -
Format: DEC
Address: 0004H
0005H
Control mode: All
Setting range: -300 to +127
Data size: 16-bit
Settings:
Input the monitoring code to P0.002 to view changes to the variable on the panel. For the list of
monitoring variables, refer to Table 8.3 Monitoring variables descriptions.
P0.003
Analog output monitoring
Default: 0x0000
Unit: -
Format: HEX
Settings:
Address: 0006H
0007H
Control mode: All
Setting range: 0x0000 to 0x0077
Data size: 16-bit
UZ Y X