Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Inspection and maintenance
Operating conditions:
Average annual ambient temperature: 30°C (86°F)
Average load rate: 80% or less
Average operating time: 20 hours per day
Inspection
frequency
Inspection item
Check if the ambient temperature and humidity are normal.
Check if the input voltage is normal.
Check if there is abnormal vibration and noise.
Daily inspection
Check if there is any abnormal smell.
Check if the servo drive has any visible damage.
Check if the ventilation holes are kept clear of dust and other foreign objects. *1
Check if the wirings are damaged or disconnected.
Check if any cable is loose or damaged.
Check if any screw is loose or damaged.
Annual inspection
Check if the servo drive, motor, and control cabinet are properly grounded.
Check if the color and temperature of the power input, power output, and regenerative
terminals are normal. *2
Note:
1. Install dust filters on the control cabinet openings, where there are fans or ventilation holes, and clean the filters
regularly. Install door seals on cabinet doors and rubber grommets on cable openings for better seal.
2. Check if the servo drive is properly wired. If the color of any terminal turns black or is abnormal, it is suggested that
you replace the terminal.