Parameters
Diagnosis parameters
Parameter
No.
Function
P4.000 Fault record (last)
Control mode
Default value
Unit
PT PR S T
0x00000000
-
O OOO
P4.001★ Fault record (second to the last)
P4.002★ Fault record (third to the last)
P4.003★ Fault record (fourth to the last)
P4.004★ Fault record (fifth to the last)
P4.005 Servo motor JOG control
P4.006■
P4.007■
Software digital output register (readable
and writable)
Multi-function for digital input
0x00000000
-
O OOO
0x00000000
-
O OOO
0x00000000
-
O OOO
0x00000000
-
O OOO
1 rpm (rotary)
20
0.01 mm/s O O O O
(linear)
0x0000
-
O OOO
0x0000
-
O OOO
P4.008★ Input status of servo drive panel (read-only)
-
-
O OOO
P4.009★ Digital output status (read-only)
P4.010▲■ Hardware calibration options
P4.011
Analog speed input 1 - hardware offset
calibration
P4.012
Analog speed input 2 - hardware offset
calibration
P4.013
P4.014
P4.015
P4.016
P4.017
Analog torque input 1 - hardware offset
calibration
Analog torque input 2 - hardware offset
calibration
Current detector (V1 phase) - hardware
offset calibration
Current detector (V2 phase) - hardware
offset calibration
Current detector (W1 phase) - hardware
offset calibration
P4.018
Current detector (W2 phase) - hardware
offset calibration
P4.019
P4.020
P4.021
P4.022
P4.023
IGBT NTC calibration level (cannot reset)
Analog monitor output (Ch1) - offset
compensation value
Analog monitor output (Ch2) - offset
compensation value
Analog speed input - offset compensation
value
Analog torque input - offset compensation
value
-
0
Factory
setting
Factory
setting
Factory
setting
Factory
setting
Factory
setting
Factory
setting
Factory
setting
Factory
setting
Factory
setting
0
0
0
0
-
O OOO
-
O OOO
-
O OOO
-
O OOO
-
O OOO
-
O OOO
-
O OOO
-
O OOO
-
O OOO
-
O OOO
-
OOO -
mV
O OOO
mV
O OOO
mV
- -O-
mV
- - -O
8
(★) Read-only parameter. Can only read the value of the parameter. For example, P0.000, P0.010, and
P4.001.
(▲) Parameter cannot be changed when servo is in Servo On status. For example, P1.000 and P1.046.
( ● ) Parameter changes become valid after power cycling. For example, P1.001 and P3.000.
( ■ ) Parameter resets to its default value after power cycling. For example, P3.006.