ASDA-A3
8
Communication parameters
Parameter
No.
P3.000● Address
Function
P3.001● Transmission speed
P3.002
P3.003
P3.004
P3.006■
P3.007
P3.009
Modbus communication protocol
Modbus communication error handling
Modbus communication timeout
Digital input (DI) control switch
Modbus communication response delay
time
Communication synchronization
P3.010 CANopen / DMCNET protocol
Default value
0x007F
0x0203 (A3-M,
A3-L, A3-E)
0x3203 (A3-F)
0x0006
0x0000
0
0x0000
1
0x5055
0x1011
P3.011 CANopen / DMCNET options
0x0000
P3.012
P3.017
P3.018
Communication support setting
CANopen B mode disconnection delay
time
EtherCAT special function switch
0x0000
1000
0x00002000
P3.022 EtherCAT PDO timeout setting
0xFF04
Control mode
Unit
PT PR S T
-
O O OO
-
O O OO
-
-
sec
-
0.5 ms
-
-
-
-
ms
-
-
O O OO
O O OO
O O OO
O O OO
O O OO
- - --
- - --
- - --
- - --
- - --
- - --
- - --
() Read-only parameter. Can only read the value of the parameter. For example, P0.000, P0.010, and
P4.001.
(▲) Parameter cannot be changed when servo is in Servo On status. For example, P1.000 and P1.046.
( ● ) Parameter changes become valid after power cycling. For example, P1.001 and P3.000.
( ■ ) Parameter resets to its default value after power cycling. For example, P3.006.
8-16