Send Quote Requests to info@automatedpt.com
ASDA-A3
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Parameters
Parameter
No.
Function
P2.020 DO3 functional planning
P2.021 DO4 functional planning
P2.022 DO5 functional planning
P2.036 DI9 functional planning
Default value
0x0109
(A3-L, A3-M)
0x0100
(A3-F, A3-E)
0x0105
(A3-L, A3-M)
0x0007
(A3-F, A3-E)
0x0007
(A3-L, A3-M)
0x0100
(A3-F, A3-E)
0x0100
Control mode
Unit
PT PR S T
-
O O OO
-
O O OO
-
O O OO
-
O O OO
P2.037 DI10 functional planning
0x0100
-
O O OO
P2.038 DI11 functional planning
0x0100
-
O O OO
P2.039 DI12 functional planning
0x0100
-
O O OO
P2.040 DI13 functional planning
0x0100
-
O O OO
P2.041
P1.038
P1.039
P1.042
P1.043
P1.047
P1.054
DO6 functional planning
0x0100
-
O
Zero speed range
Target speed detection level
10.0
1 rpm (rotary)
(panel /
1 mm/s (linear)
software) (panel / software)
O
0.1 rpm (rotary)
100
(communication)
0.1 mm/s (linear)
(communication)
3000
1 rpm (rotary)
1 mm/s (linear) O
Delay time for enabling the magnetic
brake
0
ms
O
Delay time for disabling the magnetic
brake
0
ms
O
Speed reached (DO.SP_OK) range
10
1 rpm (rotary)
1 mm/s (linear)
-
Pulse range for position reached
167772
pulse
O
O OO
O OO
O OO
O OO
O OO
- O-
O --
P1.056 Motor output overload warning level
120
%
O O OO
() Read-only parameter. Can only read the value of the parameter. For example, P0.000, P0.010, and
P4.001.
(▲) Parameter cannot be changed when servo is in Servo On status. For example, P1.000 and P1.046.
( ● ) Parameter changes become valid after power cycling. For example, P1.001 and P3.000.
( ■ ) Parameter resets to its default value after power cycling. For example, P3.006.
8
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
8-15