5. Reset after alarm:
After the alarm is cleared, the cutter has to return to where it was before the alarm
occurrence. Use the DI event trigger to enable Macro #D, set the rotary axis position scale
(P2.052) as the moving amount of the cutter in a cycle, and set E-Cam curve scaling
(P5.019) to 1.
Event 3 On
PR#53 (I)
Jump
DLY=[0] 0 ms
PR#43
PR#43 (I)
Write
DLY=[0] 0 ms
P5.093=
0x0101002E
PR#53
PR#43
PR#44
PR#45
PR#46
PR#44 (I)
Write
DLY=[0] 0 ms
P5.095=0
PR#45 (I)
Write
DLY=[0] 0 ms
P5.097=0x000D
PR#46 (I)
Position
DLY=[0] 0 ms
0 PUU
INC
500 rpm
Rising-edge triggers Event 3 to trigger the jump procedure to jump to PR#43.
Writes the deviation between the position before the alarm occurrence and the
current position to PR#46. Sets to inhibit the reverse operation.
Sets the allowable forward rate to 0%.
Executes Macro #D to calculate the deviation between the position before the
alarm occurrence and the current position.
Uses the incremental position command to move the cutter back to the position
before the alarm occurrence.
7
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
7-173