Example: when using the drive panel or communication for reading from or writing to the
data array, write values to the data array address in sequence as follows: Data array #11 =
100, Data array #12 = 200, Data array #13 = 300. Then the data is read in sequence.
1. Read / write with panel:
Set the address
for writing the
first data
Write to data array
Write
P5.011 = 11
Set the address
for reading the
first data
Read from data array
Write
P5.011 = 11
Write 100 to
Write
Data array #11 P5.012 = 100
Value of P5.011 (writing
address) adds 1
P5.011 = 12
Write 200 to
Write
Data array #12 P5.012 = 200
Value of P5.011 (writing
address) adds 1
P5.011 = 13
Write 300 to
Write
Data array #13 P5.012 = 300
P5.013
Not writable
with panel
Read
Read
Data array #11 P5.012 = 100
P5.011 (reading
address) remains
P5.011 = 11
Read
Data array #12
Write
P5.011 = 12
Read
P5.012 = 200
P5.011 (reading
address) remains
P5.011 = 12
Read
Data array #13
Write
P5.011 = 13
Read
P5.012 = 300
Read
P5.013 = 100
Value of P5.011
(reading address)
adds 1
P5.011 = 12
Read
P5.013 = 200
Value of P5.011
(reading
address) adds 1
P5.011 = 1
Read
P5.013 = 300
7-66
Send Quote Requests to info@automatedpt.com