ASDA-A3
7
7.1.5 Trigger methods for the PR command
There are six types of PR trigger methods. They are DI-triggered, Event-triggered, P5.007-
triggered, Capture-triggered (high-speed position capturing), Compare-triggered (high-speed
position comparing), and E-Cam-triggered. You can choose the most suitable trigger method
according to the applications and requirements.
Digital input (DI) triggering
You can choose the PR path to be executed by using the internal registers (Position command
Bit 0 - Bit 6) and use a command to trigger the selected PR path. Before using DI-triggering
commands, you must define the 8 sets of DI functions, which are [0x11]POS0, [0x12]POS1,
[0x13]POS2, [0x1A]POS3, [0x1B]POS4, [0x1C]POS5, [0x1E]POS6, and [0x08]CTRG (refer to
Table 8.1). You can also set these functions in the I/O screen in ASDA-Soft, as shown in Figure
7.1.5.1.
Figure 7.1.5.1 I/O screen in ASDA-Soft
Select the PR number to be executed based on the on / off status of DI.POS0 - 6 and use
DI.CTRG to trigger the specified PR path. See Figure 7.1.5.1 for an example.
7-46