7.1.4 Overview of the PR procedure
In the PR mode, there are seven types of commands. To understand how the PR procedure
works, ASDA-Soft presents the execution order and calling sequence of all PR procedures.
First, symbols and contents in the PR figure are shown. This includes five parts: number,
command execution type (property), command type, next procedure command, and command
information. See Figure 7.1.4.1.
7
(1)
PR#1 (I)(O)
(2)
Position
(3)
DLY=[0] 0 ms
100000 PUU
(4)
INC
200rpm
(5)
Figure 7.1.4.1 PR display
(1) Number: the PR number, ranging from PR#0 to PR#99 (100 sets of PR paths).
(2) Command execution type (property): (B) execute homing when power on; (O) command
overlap; (R) write data to EEPROM; (I) command interrupt.
(3) Command type: there are seven types of PR path commands: homing, speed, position,
writing, jumping, rotary axis positioning, and arithmetic operations. The color displayed in
this section depends on the command type.
(4) Next procedure command: if followed by a PR command, the arrow points to the specified
PR path.
(5) Command information: displays the details of this PR path. The displayed contents and
color depend on the information type.
The following sections illustrate each command type and its representation.
Homing methods
In the display of homing methods, PR#0 always signifies the homing procedure, which is
marked as “Homing”. See Figure 7.1.4.2.
PR#0 (B)
(1)
Homing
0:PLZ
(2)
Offset=0
(3)
PR#1
(4)
Speed1=100
(5)
Speed2=20
(6)
Figure 7.1.4.2 Homing methods display