Send Quote Requests to info@automatedpt.com
Motion Control
Speed
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA-A3
7
Target speed
Delay time
Acceleration time
Feedback speed
Command
Speed
Time
Feedback speed
Command
Target speed
Deceleration time
Delay time
Time
Figure 7.1.3.2.2 Parameters for PR mode speed control
Table 7.1.3.2.1 Bit function of PR speed control
PR parameters
Command type
D
C
B
A
U
Z
Y
X
-
-
DLY
-
DEC ACC OPT 1
Data Content
Target speed [0.1 rpm / PPS]
Note:
1. Y: OPT: option
BIT
3
2
1
0
Command type
-
UNIT
AUTO
INS
INS: interrupt command that interrupts the previous motion command.
AUTO: automatically loads the next PR command when the current one is complete.
UNIT: speed unit selection; 0 signifies 0.1 rpm and 1 signifies PPS.
2. Z, U: ACC / DEC: acceleration / deceleration time, set by P5.020 - P5.035.
3. B: DLY: delay time, set by P5.040 - P5.055.
7-24
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com