P5.005
High speed homing (first speed setting)
Address: 050AH
050BH
Operation
interface:
Panel
/
software
Communication Control mode: PR (set with P5.004)
Default:
100.0 (rotary)*
1000 (linear)*
1000
Data size: 32-bit
1 rpm (rotary)*
Unit: 1 μm/s (linear)*
0.1 rpm (rotary)*
1 μm/s (linear)*
0.1 to 2000.0 (rotary)*
Setting range: 1 to 15999999 (linear)*
1 to 20000 (rotary)*
1 to 15999999 (linear)*
Format: DEC
DEC
-
-
Example:
1.5 = 1.5 rpm
15 = 15 μm/s
15 = 1.5 rpm
15 = 15 μm/s
-
-
Settings:
The first speed setting for high speed homing.
First high speed homing
First high speed homing
Second low speed homing
7
Z Pulse
ORG
Second low speed homing
ORG
Z Pulse
Note: rotary means a permanent-magnet synchronous rotary motor; linear means a permanent-magnet synchronous
linear motor.
P5.006
Low speed homing (second speed setting)
Address: 050CH
050DH
Operation
interface:
Panel
/
software
Communication Control mode: PR (set with P5.004)
Default:
20.0 (rotary)*
200 (linear)*
200
Data size: 32-bit
1 rpm (rotary)*
Unit: 1 μm/s (linear)*
0.1 rpm (rotary)*
1 μm/s (linear)*
0.1 to 500.0 (rotary)*
Setting range:
1 to 15999999 (linear)*
1 to 5000 (rotary)*
1 to 15999999 (linear)*
Format: DEC
DEC
-
-
Example:
1.5 = 1.5 rpm
15 = 15 μm/s
15 = 1.5 rpm
15 = 15 μm/s
-
-
Settings:
The second speed setting for low speed homing.
Note: rotary means a permanent-magnet synchronous rotary motor; linear means a permanent-magnet synchronous