Control Mode
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA-A3
6
6.7.4.11 Full-closed loop feedback source for the controller
P3.013
Controller’s full-closed loop feedback
Address: 031AH
031BH
Default: 0x0000
Control mode: PR* (full-closed loop)
Unit: -
Setting range: 0x0000 - 0x0022
Format: HEX
Data size: 16-bit
Settings:
UZ YX
X
Encoder feedback source in full-closed loop
control
Z Reserved
Y
Z phase offset source in full-closed loop
mode
U Reserved
X: encoder feedback source in full-closed loop control (the source displayed in the Feedback
position [PUU])
0: motor encoder feedback
1: auxiliary encoder feedback
2: in semi-closed loop control, it is the motor encoder feedback; in full-closed loop control, it is the
auxiliary encoder feedback.
Y: Z phase offset source in full-closed loop mode
0: motor
1: auxiliary encoder
2: in semi-closed loop control, it is the motor’s Z phase offset; in full-closed loop control, it is the
auxiliary encoder’s Z phase offset.
Note:
1. This parameter setting is different from P1.074.Y (switch between motor encoder and auxiliary encoder).
This parameter only modifies the feedback signal source uploaded to the controller. It is suggested that you set
P3.013 to 0x0022 to avoid misoperation when the motor is in the Servo On state.
2. PR full-closed loop function is not yet supported.
6-60