6.7.4.10 Encoder output settings
P1.003
Encoder pulse output polarity
Default: 0x0000
Unit: -
Format: HEX
Settings:
Address: 0106H
0107H
Control mode: All
Setting range: 0x0000 – 0x0013
Data size: 16-bit
UZ YX
X Polarity of monitor analog output
Y Direction of encoder pulse output
Z Reserved
U Reserved
X: polarity of monitor analog output
0: MON1(+), MON2(+)
1: MON1(+), MON2(-)
2: MON1(-), MON2(+)
3: MON1(-), MON2(-)
Y: direction of encoder pulse output
0: positive direction
1: negative direction
6-58
P1.046Encoder pulse number output (OA, OB)
Default: 2500
Control mode: All
Address: 015CH
015DH
Unit: pulse
Setting range: 1 - 536870912
Format: DEC
Data size: 32-bit
Settings:
Rotary motor: the number of single-phase pulse outputs per revolution; the maximum output frequency
of the hardware is 19.8 MHz.
Linear motor: the number of single-phase pulse outputs per meter; the maximum output frequency of
the hardware is 19.8 MHz.
For the OA and OB settings of CN2 and CN5, refer to P1.074.Y (Selection of OA/OB output source) and
P1.097 (Encoder output denominator (OA, OB)).
Note:
In the following circumstances, pulse output of the encoder may exceed the maximum allowable output pulse
frequency of the drive, causing AL018 or AL048:
1. Encoder error.
2. The motor speed is faster than P1.076.
3. Rotary motor: if P1.074.Y = 0 and P1.097 = 0, motor speed (rpm)/60 x P1.046 x 4 > 19.8 x 106.
Linear motor: if P1.074.Y = 1 and P1.097 = 1, motor speed (μm/s) x P1.046 > 19.8 x 106.