Send Quote Requests to info@automatedpt.com
Control Mode
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA-A3
6
Error clearing disabled (P1.084.X = 1)
Feedback
position
Diagram of error clearing when the system switches
between full- and semi-closed loop modes
P1.084.X = 1
Auxiliary encoder
Motor encoder
22000
21000
20000
19000
11000
10000
After the system
switches from the
semi-closed loop to
full-closed loop mode,
the error is not cleared
and the position moves.
Control mode
Full-closed loop Semi-closed loop Full-closed loop
(Stage 1)
(Stage 2)
(Stage 3)
Stage 1: full-closed loop control (feedback position of the auxiliary encoder)
If the servo drive issued a position command of 10,000 PUU and the feedback position of the auxiliary
encoder is 10,000 PUU, the final feedback position of the motor encoder is 11,000 PUU due to the
backlash and sliding of the mechanical parts.
Stage 2: semi-closed loop control (feedback position of the motor encoder)
Use DI [0x0B] to switch the control mode from full-closed loop to semi-closed loop, and then issue the
position command of 10,000 PUU again. In semi-closed loop control, since the command refers to the
position of the motor encoder, the feedback position of the motor encoder is 21,000 PUU, but the feedback
position of the auxiliary encoder is 19,000 PUU.
In this mode, there is an error of 1,000 PUU between the auxiliary encoder (19,000 PUU) and the position
command (20,000 PUU).
Stage 3: full-closed loop control (feedback position of the auxiliary encoder)
When you set P1.084 to 1, the error will not be cleared. Thus, after using DI [0x0B] to switch the control
mode from semi-closed loop to full-closed loop, the feedback position of the auxiliary encoder is corrected
and the motor moves to the corresponding position (yellow area as shown in the above figure). The
previous semi-closed loop command becomes the full-closed loop command and refers to the auxiliary
encoder to move the mechanical part to the position corresponding to the actual command. The final
feedback position of the auxiliary encoder is 20,000 PUU.
6-54
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com