Control Mode
6.7.4.2 Auxiliary encoder resolution setting
P1.072
Address: 0190H
Resolution of auxiliary encoder for full-closed loop control
0191H
Default: 5000
Control mode: PT / PR* (full-closed loop)
Unit: pulse/rev
Setting range: 200 - 1280000
Format: DEC
Data size: 32-bit
Settings:
The number of A/B pulses corresponding to a full-closed loop when the motor runs a cycle (after
quadruple frequency).
Note: PR full-closed loop function is not yet supported.
There are two methods for calculating the corresponding pulse number of the auxiliary encoder
per motor revolution. One method calculates the theoretical value from the physical quantity.
The other calculates the actual value with the Scope function of ASDA-Soft. If the resolution of
auxiliary encoder for full-closed loop control (P1.072) is incorrectly set, the position error
between the auxiliary encoder feedback and the motor encoder accumulates during long-term
operation, triggering AL040.
1. Calculating the theoretical value
If the machine using screw transmission forms a full-closed loop control system with the
auxiliary encoder, the screw pitch and resolution of the auxiliary encoder are required for
calculating the corresponding pulse number of the auxiliary encoder per motor revolution.
When the specifications of the screw and auxiliary encoder are known, you can calculate
the value of P1.072.
Example:
If the screw pitch is 5 mm and the resolution of the linear scale (auxiliary encoder) is 0.5 µm,
the calculation is as follows.
5 mm 5000 μm
0.5 μm = 0.5 μm = 10000 pulse = P1.072
When the motor runs a cycle, the linear scale requires to receive 10,000 pulses.