Control Mode
Here are the steps for checking the directions.
Step 1: disable the full-closed loop function by setting P1.074.X to 0.
6
Step 2: open the Scope function of ASDA-Soft, select Feedback position [PUU] for CH1 and
Auxiliary encoder feedback [Pulse] for CH2, and then click Start to start the scope.
CH1 32 bit
[IDX] Normal
CH2 32 bit
[IDX] Normal
Feedback position
[PUU]
Auxiliary encoder
feedback [Pulse]
Use the JOG function to operate the motor in a single direction at a low speed. If you get two
feedback signals which are in inverse directions (shown as follows), go on to Step 3 to adjust
the parameter.
Note: set P3.013.X to 0 when checking the directions.
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
6-45