Control Mode
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA-A3
6
3. When setting the full-closed loop function for the first time, do not set the value of P1.073 too great to
prevent the auxiliary encoder from disconnection or prevent the motor from continuous operation
caused by inverse direction.
4. This parameter is not available in PR mode. In PR mode, the error is automatically cleared when the
system switches between full- and semi-closed loops.
5. PR full-closed loop function is not yet supported.
6.7.4 Parameters for full-closed loop function
6.7.4.1 Auxiliary encoder direction setting
P1.074
Full-closed loop control switch
Default: 0x0000
Address: 0194H
0195H
Control mode: PT / PR* (full-closed loop)
Unit: -
Setting range: 0000h - F132h
Format: HEX
Data size: 16-bit
Settings:
UZ YX
X
Full-closed loop / Gantry function
switch
Y
Selection of OA / OB / OZ output
source
Z
Feedback direction (positive / negative) of
auxiliary encoder
U Filter width setting for CN5 feedback pulse
Z: feedback direction (positive / negative) of auxiliary encoder
0: pulse output in positive direction
1: pulse output in negative direction
Note: PR full-closed loop function is not yet supported.
Before using the full-closed loop control function, check if the feedback position of the auxiliary
encoder increases or decreases in the same direction as the motor encoder. If the feedback
directions are inverse, change the setting value of P1.074.Z to reverse the direction for the
signal of the auxiliary encoder.