Send Quote Requests to info@automatedpt.com
ASDA-A3
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Control Mode
6.7.3 Steps for setting the full-closed loop function
Check the wiring*1
P1.074.Z
Direction setting of auxiliary encoder feedback
6
P1.072
Auxiliary encoder resolution setting
P1.044, P1.045
E-Gear ratio setting*2
P1.073
Protection range for the feedback position
deviation between the main encoder and auxiliary
encoder*3
P1.075
Low-pass filter time constant for full- / semi-closed
loop control
P1.084
Error clearing function when switching between
full- and semi-closed loops*4
P1.085
Auto clearing of the feedback position error
between the main encoder and auxiliary encoder
Set DI [0x0B] to switch between
full- and semi-closed loop
P2.080
Z phase source of homing (only available in PR)*5
P1.003.Y, P1.046, P1.076, P2.066
Encoder output setting
P3.013
Full-closed loop feedback setting in PR (controller)
P1.074.X
Enable the full-closed loop function
Note:
1. The auxiliary encoder (A, B, and Z phase signals) is connected to the CN5 on the servo drive to form
a full-closed loop. You can monitor whether the drive receives the feedback position from the auxiliary
encoder with P5.017.
2. Set the E-Gear ratio to 1 : 1.
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
6-43