Send Quote Requests to info@automatedpt.com
Control Mode
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
ASDA-A3
6
Full-closed loop control structure in PR mode
The servo is in full-closed loop control in PR mode when you enable the full-closed loop function
in the communication mode (with P1.001 set to B or C). When the servo is in full-closed loop
control in PR mode, if the E-Gear ratio is set to 1, one PUU from the command corresponds to
1
one quadruple-frequency pulse from the auxiliary encoder. If the E-Gear ratio is set to 2, one PUU
1
from the command corresponds to two quadruple-frequency pulses from the auxiliary encoder.
Note: PR full-closed loop function is not yet supported.
GNUM0, GNUM1
Internal PR
command
1st numerator P1.044
2nd numerator P2.060
3rd numerator P2.061
4th numerator P2.062
Denominator P1.045
Error
counter
P1.084
Function when switching
to full-closed loop
(set to 0 to clear the error
when switching)
Position
control gain
P2.000
Speed loop
Speed
estimation
Pulse number per
motor rotation
P1.072
DI 0x0B
Full- / semi-closed loop switch
Encoder
Encoder
OA
pulse
pulse
OB
output
number
OZ
polarity
output
P1.003
P1.046
P1.074 Selection of
OA/OB/OZ output
source
P1.073
Protection range for the
feedback position
deviation between the
main encoder and
auxiliary encoder in
full-closed loop
Error
counter
P1.072
Pulse number per
motor rotation
Motor pulse
counter
Low-pass
filter
P1.075
Motor
Machine
Encoder
CN5
Auxiliary
encoder
6-42
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com